{"id":5539,"date":"2018-07-03T11:38:53","date_gmt":"2018-07-03T11:38:53","guid":{"rendered":"https:\/\/www.krohne-inor.se\/?page_id=5539\/?page_id=5539"},"modified":"2025-06-09T12:29:35","modified_gmt":"2025-06-09T12:29:35","slug":"pt100-matosakerhet-och-matavvikelser","status":"publish","type":"page","link":"https:\/\/inor.stagingidentitet.se\/?page_id=5539","title":{"rendered":"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h1>Pt100 &#8211; M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser<\/h1>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser<\/h2>\n<p>F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen<br \/>\n1. Svarstid *<br \/>\n2. Insticksl\u00e4ngd<br \/>\n3. Avvikelse fr\u00e5n f\u00f6reskrivet montage<br \/>\n4. Egenuppv\u00e4rmning<br \/>\n5. Vibrationer och andra mekaniska belastningar *<br \/>\n6. Omgivningstemperaturen\/V\u00e4rmeavledning *<br \/>\n7. Avvikelser hos m\u00e4telementet avseende\u00a0grundv\u00e4rdena<br \/>\n8. Kemiska reaktioner *<br \/>\n9. Joniserande str\u00e5lning<br \/>\n10. Givarens inre isolationsmotst\u00e5nd<br \/>\n11. Inducerade termosp\u00e4nningar<br \/>\n12. Elektriska och magnetiska st\u00f6rf\u00e4lt<br \/>\n13. Termisk belastning *<br \/>\n14. Friktion fr\u00e5n mediefl\u00f6det<br \/>\n15. V\u00e4rmestr\u00e5lning<br \/>\n<em>* se beskrivningarna nedan f\u00f6r ytterligare information.<\/em><\/p>\n<p>D\u00e5 det som synes \u00e4r en hel rad faktorer, som kan\u00a0f\u00f6rvr\u00e4nga ett temperaturv\u00e4rde \u00e4r det av vikt att\u00a0inf\u00f6r varje enskild m\u00e4tning noggrant unders\u00f6ka vilka\u00a0f\u00f6ruts\u00e4ttningar, som g\u00e4ller.<br \/>\nINORs specialister har l\u00e5ng erfarenhet och kan ge praktisk r\u00e5dgivning f\u00f6r s\u00e5v\u00e4l enkla som komplicerade m\u00e4tningar.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;felkallor&#8221;]<\/p>\n<h2>Fel p\u00e5 grund av mekanisk belastning<\/h2>\n<p>Tryck, vibrationer och b\u00f6jning \u00e4r de vanligaste\u00a0mekaniska belastningarna temperaturgivare uts\u00e4tts\u00a0f\u00f6r. M\u00e4tmotst\u00e5nd, utsatta f\u00f6r tryck eller b\u00f6jning, \u00e4ndrar motst\u00e5ndsv\u00e4rdet mer eller mindre beroende p\u00e5\u00a0konstruktionen. F\u00f6r\u00e4ndringen blir st\u00f6rre ju fastare\u00a0f\u00f6rbindningen mellan motst\u00e5ndsmetallen och dess\u00a0stomme \u00e4r. En temperaturgivare m\u00e5ste d\u00e4rf\u00f6r\u00a0konstrueras s\u00e5 att belastningar ej \u00f6verf\u00f6rs till<br \/>\nm\u00e4tmotst\u00e5ndet. Kraftiga vibrationer kan leda till\u00a0avbrott p\u00e5 interna ledare och skyddsr\u00f6r. I skaks\u00e4kra motst\u00e5ndsgivare\u00a0m\u00e5ste d\u00e4rf\u00f6r de interna ledarna ges minsta m\u00f6jliga\u00a0r\u00f6relsefrihet. I temperaturgivare utsatta f\u00f6r tryck eller\u00a0b\u00f6jbelastningar skall d\u00e4remot tilledningarna ges\u00a0st\u00f6rsta m\u00f6jliga r\u00f6relsefrihet f\u00f6r att d\u00e4rigenom\u00a0f\u00f6rhindra \u00f6verf\u00f6ring av belastningen.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8837&#8243; img_size=&#8221;large&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>Fel p\u00e5 grund av kemiska reaktioner<\/h2>\n<p>Korrosionsbest\u00e4ndigheten i en motst\u00e5ndsgivares\u00a0skyddsarmatur \u00e4r den avg\u00f6rande faktorn vid kemisk\u00a0p\u00e5verkan. Det \u00e4r d\u00e4rf\u00f6r ytterst viktigt att armaturen\u00a0tillverkas i ett material, som passar dels processk\u00e4rlet,\u00a0dels processmediet och dels den h\u00f6gsta\u00a0f\u00f6rekommande medietemperaturen. Givartillverkaren\u00a0m\u00e5ste s\u00e4kerst\u00e4lla att m\u00e4tinsatsen \u00e4r t\u00e4tad f\u00f6r att\u00a0f\u00f6rhindra att fukt tr\u00e4nger igenom. Vid h\u00f6g\u00a0temperatur kan dessutom stark syrebrist vid m\u00e4tmotst\u00e5ndet\u00a0medf\u00f6ra reaktionsf\u00f6rlopp i m\u00e4tmotst\u00e5ndets\u00a0keramiska stomme, vilket leder till att metaller\u00a0diffunderar in i m\u00e4ttr\u00e5den. Till f\u00f6ljd av detta, kan de elektriska egenskaperna f\u00f6r\u00e4ndras.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8862&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>P\u00e5verkan av termisk belastning<\/h2>\n<p>Pt100 element har praktiskt taget ingen oxidationsben\u00e4genhet.\u00a0D\u00e4remot kan de elektriska v\u00e4rdena driva\u00a0beroende p\u00e5 bl.a. m\u00e4tmotst\u00e5ndets konstruktion samt\u00a0hur n\u00e4ra temperaturgr\u00e4nsen man befinner sig.\u00a0F\u00f6r\u00e4ndringarna orsakas oftast av f\u00f6roreningar i\u00a0metallen och i de omgivande isolationsmaterialen.\u00a0Termisk belastning kan dessutom minska isolationsmotst\u00e5ndet,\u00a0vilket m\u00e4rkbart kan p\u00e5verka m\u00e4tresultatet.[\/vc_column_text][vc_single_image image=&#8221;8848&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8937&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>Fel p\u00e5 grund av v\u00e4rmeavledning<\/h2>\n<p>Temperaturm\u00e4tning med ber\u00f6ringsgivare f\u00f6ruts\u00e4tter att\u00a0givaren kommer i direkt kontakt med mediet,\u00a0antingen genom att givaren doppas in i mediet, som\u00a0d\u00e5 helt omsluter den temperaturk\u00e4nsliga delen, eller\u00a0genom att givaren l\u00e4gges an mot mediets yta. I b\u00e5da\u00a0fallen st\u00f6rs den befintliga v\u00e4rmestr\u00f6mningen eftersom\u00a0givaren transporterar v\u00e4rme fr\u00e5n mediet till\u00a0omgivningen.<br \/>\nSpeciellt vid m\u00e4tning av yttemperatur \u00e4r felet p.g.a.\u00a0v\u00e4rmeavledning framtr\u00e4dande. Ytans utstr\u00e5lning, och\u00a0d\u00e4rmed ocks\u00e5 temperaturprofilen, \u00e4ndras omkring\u00a0m\u00e4tst\u00e4llet. M\u00e4tnoggrannheten f\u00f6rb\u00e4ttras avsev\u00e4rt om\u00a0givaren har:<\/p>\n<ul>\n<li>liten massa och volym<\/li>\n<li>god v\u00e4rmekontakt<\/li>\n<li>liten v\u00e4rmeledningsf\u00f6rm\u00e5ga till omgivningen<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8845&#8243; img_size=&#8221;large&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;matvardesomvandlare&#8221;]<\/p>\n<h2>M\u00e4tv\u00e4rdesomvandlare<\/h2>\n<p>M\u00e4tv\u00e4rdesomvandlare anv\u00e4nds f\u00f6r omvandling av en motst\u00e5ndsgivares resistansv\u00e4rde till en process-anpassad m\u00e4tsignal. F\u00f6r anslutning av givaren till omvandlaren till\u00e4mpas tre olika anslutningsmetoder: 2-, 3- och 4-ledaranslutning. I samtliga anslutnings\u00adformer s\u00e4nder omvandlaren en konstant str\u00f6m genom m\u00e4tmotst\u00e5ndet, som man sedan m\u00e4ter sp\u00e4nningsfallet \u00f6ver. Omvandlare tillverkas i 2- resp. 4-tr\u00e5dsutf\u00f6rande (ej att f\u00f6rv\u00e4xla med 2- resp. 4-ledaranslutning). I 4-tr\u00e5ds-utf\u00f6rande matas omvandlaren genom tv\u00e5 separata ledare (d\u00e4rav beteckningen separatmatad) skilda fr\u00e5n utg\u00e5ngens tv\u00e5 ledare.<\/p>\n<p>I 2-tr\u00e5dsutf\u00f6rande matas omvandlaren via utg\u00e5ngens b\u00e5da ledare vilka d\u00e4rigenom uppfyller dubbla funktioner. D\u00e4rav f\u00f6ljer automatiskt att en 2-tr\u00e5dsomvandlares utsignal pga. egenf\u00f6rbrukningen ej kan g\u00e5 ned till 0, utan har ett l\u00e4gsta v\u00e4rde av 4 mA. Standardspannet (processnorm) blir d\u00e4rf\u00f6r 4-20 mA. Utsignalen fr\u00e5n en 4-tr\u00e5dsomvandlare kan d\u00e4remot f\u00e5s att anta godtyckliga processignalv\u00e4rden.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Ing\u00e5ng<\/h3>\n<p>M\u00e4tv\u00e4rdesomvandlare anv\u00e4nds f\u00f6r omvandling av en motst\u00e5ndsgivares resistansv\u00e4rde till en process-anpassad m\u00e4tsignal. F\u00f6r anslutning av givaren till omvandlaren till\u00e4mpas normalt tre olika anslutningsmetoder: 2-, 3- och 4-ledaranslutning. I samtliga anslutnings\u00adformer s\u00e4nder omvandlaren en konstant str\u00f6m genom m\u00e4tmotst\u00e5ndet, som man sedan m\u00e4ter sp\u00e4nningsfallet \u00f6ver. Det \u00e4r viktigt att m\u00e4tstr\u00f6mmen h\u00e5lls liten f\u00f6r att minimera egenuppv\u00e4rmningen. En bra omvandlare avger en m\u00e4tstr\u00f6m som ligger under 1 mA.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-medium wp-image-8702\" src=\"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg\" alt=\"\" width=\"300\" height=\"65\" srcset=\"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg 300w, https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang.jpg 553w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Utg\u00e5ng<\/h3>\n<p>Omvandlare tillverkas i 2- resp. 4-tr\u00e5dsutf\u00f6rande (ej att f\u00f6rv\u00e4xla med 2- resp. 4-ledaranslutning). I 4-tr\u00e5ds-utf\u00f6rande matas omvandlaren genom tv\u00e5 separata ledare (d\u00e4rav beteckningen separatmatad) skilda fr\u00e5n utg\u00e5ngens tv\u00e5 ledare.<\/p>\n<p>I 2-tr\u00e5dsutf\u00f6rande matas omvandlaren via utg\u00e5ngens b\u00e5da ledare vilka d\u00e4rigenom uppfyller dubbla funktioner. D\u00e4rav f\u00f6ljer automatiskt att en 2-tr\u00e5dsomvandlares utsignal pga. egenf\u00f6rbrukningen ej kan g\u00e5 ned till 0, utan har ett l\u00e4gsta v\u00e4rde av 4 mA. Standardspannet (processnorm) blir d\u00e4rf\u00f6r 4-20 mA. Utsignalen fr\u00e5n en 4-tr\u00e5dsomvandlare kan d\u00e4remot f\u00e5s att anta godtyckliga processignalv\u00e4rden som 0 &#8211; 20 mA, 4 \u2013 20 mA, 0-5 V eller 1 &#8211; 5 V.<\/p>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-medium wp-image-8703\" src=\"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-utgang-300x143.jpg\" alt=\"\" width=\"300\" height=\"143\" srcset=\"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-utgang-300x143.jpg 300w, https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-utgang.jpg 543w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221; el_id=&#8221;givarbrott&#8221;]<\/p>\n<h2>Givarbrott<\/h2>\n<p>De stora p\u00e5frestningarna temperaturgivare uts\u00e4tts f\u00f6r kan medf\u00f6ra risk f\u00f6r elektriskt avbrott inuti givaren.\u00a0Avbrottet kan drabba tilledningarna eller ocks\u00e5 kan\u00a0m\u00e4tmotst\u00e5ndet skadas. Samtliga dessa fel g\u00e5r under\u00a0namnet givarbrott. Den vanligaste orsaken till givarbrott\u00a0\u00e4r vibrationer i eller omkring den kritiska\u00a0frekvensen. En modern omvandlare ger signal vid\u00a0givarbrott. Detta sker genom att utsignalen g\u00e5r till ett\u00a0f\u00f6rbest\u00e4mt v\u00e4rde, vanligast strax ovanf\u00f6r 20 mA.<br \/>\nKonsekvent givarbrottskydd inneb\u00e4r att omvandlaren signalerar, dvs utsignalen g\u00e5r till ett f\u00f6rutbest\u00e4mt v\u00e4rde, oavsett i vilken ledare avbrottet har \u00e4gt rum (viktigt att veta vid 3- eller 4-ledaranslutning). Hos INORs programmerbara omvandlare best\u00e4mmer anv\u00e4ndaren sj\u00e4lv utsignalens v\u00e4rde vid givarbrott.<\/p>\n<p>OBS! N\u00e4r givarens isolationsmotst\u00e5nd sjunker under en viss niv\u00e5 kan det intr\u00e4ffa att omvandlaren uppfattar det l\u00e5ga isolationsmotst\u00e5ndet som ett m\u00e4tv\u00e4rde i st\u00e4llet f\u00f6r det motst\u00e5nd som m\u00e4tmotst\u00e5ndet intar. P\u00e5f\u00f6ljden blir att omvandlaren luras att tro att m\u00e4tkedjan \u00e4r intakt \u00e4ven sedan ett givarbrott \u00e4gt rum. De flesta INOR-omvandlare har en funktion, SmartSense, som kontinuerligt \u00f6vervakar temperaturgivarens isolationsresistans och ger signal n\u00e4r denna \u00e4r f\u00f6r l\u00e5g.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8966&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;linjarisering&#8221;]<\/p>\n<h2>Linj\u00e4risering<\/h2>\n<p>Med temperaturlinj\u00e4risering menas att en omvandlare alltid l\u00e4mnar samma f\u00f6r\u00e4ndring av utsignalen f\u00f6r en viss f\u00f6r\u00e4ndring av in-temperaturen oberoende av var inom m\u00e4tspannet denna f\u00f6r\u00e4ndring sker. F\u00f6rh\u00e5llandet temperatur\/utsignal blir d\u00e4rf\u00f6r en r\u00e4t linje. F\u00f6r motst\u00e5ndslinj\u00e4ra omvandlare \u00e4r d\u00e4remot \u00f6verf\u00f6ringen olinj\u00e4r ur temperatur-h\u00e4nseende som medf\u00f6r olika stora f\u00f6r\u00e4ndringar av utsignalen inom m\u00e4tspannets olika delar. Hos digitala omvandlare kan man l\u00e4tt st\u00e4lla om mellan motst\u00e5nds- och temperaturlinj\u00e4ritet.[\/vc_column_text][vc_single_image image=&#8221;8866&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;ledaranslutning&#8221;]<\/p>\n<h2>2-ledaranslutning<\/h2>\n<p>I en 2-ledaranslutning ligger motst\u00e5ndet fr\u00e5n anslutningsledningarna i serie med m\u00e4tmotst\u00e5ndet. F\u00f6r\u00e4ndringar i tilledningarnas motst\u00e5nd kommer d\u00e4rf\u00f6r att direkt p\u00e5verka m\u00e4tresultatet. P.g.a. de up\u00adpenbara nackdelarna anv\u00e4nds denna form s\u00e4llan och b\u00f6r anv\u00e4ndas med f\u00f6rsiktighet.<\/p>\n<p>M\u00e4tfel p.g.a. ledningarnas motst\u00e5nd \u00e4r i regel cirka 2,6 \u00b0C per ohm f\u00f6r en Pt100-givare och 10 g\u00e5nger mindre f\u00f6r Pt1000. Om ledningsmotst\u00e5ndet \u00e4r k\u00e4nt, kan signalomvandlaren justeras manuellt f\u00f6r att kompens\u00adera ledningsmotst\u00e5ndet. Eftersom detta \u00e4r en fast jus\u00adtering, kommer f\u00f6r\u00e4ndringar i ledningsmotst\u00e5ndet p\u00e5 grund av temperaturvariationer inte att kompenseras.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8947&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>3-ledaranslutning<\/h2>\n<p>Detta \u00e4r den vanligast f\u00f6rekommande formen f\u00f6r anslutning. 3-ledaranslutning f\u00f6ruts\u00e4tter att resistansen i de tre ledarna \u00e4r lika. Normalt elimin\u00aderar den i stort sett inverkan av f\u00f6r\u00e4ndringar i tilledningarna s\u00e5 l\u00e4nge dessa f\u00f6r\u00e4ndringar \u00e4r lika i de tre ledarna (hos INORs IPAQ-signalomvandlare \u00e4r inverkan helt eliminerad). F\u00f6r omvandlare inbyggda i givarens anslutningshuvud \u00e4r 3-ledaranslutning den mest anv\u00e4nda metoden.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8948&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>4-ledaranslutning<\/h2>\n<p>4-ledaranslutning anv\u00e4nds vid noggranna m\u00e4tningar. M\u00e4tstr\u00f6mmen leds genom tv\u00e5 ledningar och sp\u00e4nningsfallet m\u00e4ts \u00f6ver de tv\u00e5 \u00e5terst\u00e5ende. H\u00e4rigenom elimineras alla motst\u00e5ndsf\u00f6r\u00e4ndringar i tilledningarna, \u00e4ven n\u00e4r dessa skiljer sig fr\u00e5n varandra. De flesta moderna signalomvandlare st\u00f6djer denna rekommenderade anslutning.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8949&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<p style=\"text-align: right;\"><span style=\"text-decoration: underline;\"><a href=\"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/\">Tillbaka till Temperaturskolan<\/a><\/span><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<br \/>\nPt100 &#8211; M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser<br \/>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;]<br \/>\nM\u00e4tos\u00e4kerhet och m\u00e4tavvikelser<br \/>\nF\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen<br \/>\n1. Svarstid *<br \/>\n2. Insticksl\u00e4ngd<br \/>\n3. Avvikelse fr\u00e5n f\u00f6reskrivet montage<br \/>\n4. Egenuppv\u00e4rmning<br \/>\n5. Vibrationer och andra mekaniska belastningar *<br \/>\n6. Omgivningstemperaturen\/V\u00e4rmeavledning *<br \/>\n7. Avvikelser hos m\u00e4telementet avseende\u00a0grundv\u00e4rdena<br \/>\n8. Kemiska reaktioner *<br \/>\n9. Joniserande str\u00e5lning<br \/>\n10. Givarens inre isolationsmotst\u00e5nd<br \/>\n11. Inducerade termosp\u00e4nningar<br \/>\n12. Elektriska och magnetiska st\u00f6rf\u00e4lt<br \/>\n13. Termisk belastning *<br \/>\n14. Friktion fr\u00e5n mediefl\u00f6det<br \/>\n15. V\u00e4rmestr\u00e5lning<br \/>\n* se beskrivningarna nedan f\u00f6r ytterligare information.<br \/>\nD\u00e5 det som synes \u00e4r en hel rad faktorer, som kan\u00a0f\u00f6rvr\u00e4nga ett temperaturv\u00e4rde \u00e4r det av vikt att\u00a0inf\u00f6r varje enskild m\u00e4tning noggrant unders\u00f6ka vilka\u00a0f\u00f6ruts\u00e4ttningar, som g\u00e4ller.<br \/>\nINORs specialister har l\u00e5ng erfarenhet och kan ge praktisk r\u00e5dgivning f\u00f6r s\u00e5v\u00e4l enkla som komplicerade m\u00e4tningar.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;felkallor&#8221;]<br \/>\nFel p\u00e5 grund av mekanisk belastning<br \/>\nTryck, vibrationer och b\u00f6jning \u00e4r de vanligaste\u00a0mekaniska belastningarna temperaturgivare uts\u00e4tts\u00a0f\u00f6r. M\u00e4tmotst\u00e5nd, utsatta f\u00f6r tryck eller b\u00f6jning, \u00e4ndrar motst\u00e5ndsv\u00e4rdet mer eller mindre beroende p\u00e5\u00a0konstruktionen. F\u00f6r\u00e4ndringen blir st\u00f6rre ju fastare\u00a0f\u00f6rbindningen mellan motst\u00e5ndsmetallen och dess\u00a0stomme \u00e4r. En temperaturgivare m\u00e5ste d\u00e4rf\u00f6r\u00a0konstrueras s\u00e5 att belastningar ej \u00f6verf\u00f6rs till<br \/>\nm\u00e4tmotst\u00e5ndet. Kraftiga vibrationer kan leda till\u00a0avbrott p\u00e5 interna ledare och skyddsr\u00f6r. I skaks\u00e4kra motst\u00e5ndsgivare\u00a0m\u00e5ste d\u00e4rf\u00f6r de interna ledarna ges minsta m\u00f6jliga\u00a0r\u00f6relsefrihet. I temperaturgivare utsatta f\u00f6r tryck eller\u00a0b\u00f6jbelastningar skall d\u00e4remot tilledningarna ges\u00a0st\u00f6rsta m\u00f6jliga r\u00f6relsefrihet f\u00f6r att d\u00e4rigenom\u00a0f\u00f6rhindra \u00f6verf\u00f6ring av belastningen.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8837&#8243; img_size=&#8221;large&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\nFel p\u00e5 grund av kemiska reaktioner<br \/>\nKorrosionsbest\u00e4ndigheten i en motst\u00e5ndsgivares\u00a0skyddsarmatur \u00e4r den avg\u00f6rande faktorn vid kemisk\u00a0p\u00e5verkan. Det \u00e4r d\u00e4rf\u00f6r ytterst viktigt att armaturen\u00a0tillverkas i ett material, som passar dels processk\u00e4rlet,\u00a0dels processmediet och dels den h\u00f6gsta\u00a0f\u00f6rekommande medietemperaturen. Givartillverkaren\u00a0m\u00e5ste s\u00e4kerst\u00e4lla att m\u00e4tinsatsen \u00e4r t\u00e4tad f\u00f6r att\u00a0f\u00f6rhindra att fukt tr\u00e4nger igenom. Vid h\u00f6g\u00a0temperatur kan dessutom stark syrebrist vid m\u00e4tmotst\u00e5ndet\u00a0medf\u00f6ra reaktionsf\u00f6rlopp i m\u00e4tmotst\u00e5ndets\u00a0keramiska stomme, vilket leder till att metaller\u00a0diffunderar in i m\u00e4ttr\u00e5den. Till f\u00f6ljd av detta, kan de elektriska egenskaperna f\u00f6r\u00e4ndras.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8862&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\nP\u00e5verkan av termisk belastning<br \/>\nPt100 element har praktiskt taget ingen oxidationsben\u00e4genhet.\u00a0D\u00e4remot kan de elektriska v\u00e4rdena driva\u00a0beroende p\u00e5 bl.a. m\u00e4tmotst\u00e5ndets konstruktion samt\u00a0hur n\u00e4ra temperaturgr\u00e4nsen man befinner sig.\u00a0F\u00f6r\u00e4ndringarna orsakas oftast av f\u00f6roreningar i\u00a0metallen och i de omgivande isolationsmaterialen.\u00a0Termisk belastning kan dessutom minska isolationsmotst\u00e5ndet,\u00a0vilket m\u00e4rkbart kan p\u00e5verka m\u00e4tresultatet.[\/vc_column_text][vc_single_image image=&#8221;8848&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8937&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\nFel p\u00e5 grund av v\u00e4rmeavledning<br \/>\nTemperaturm\u00e4tning med ber\u00f6ringsgivare f\u00f6ruts\u00e4tter att\u00a0givaren kommer i direkt kontakt med mediet,\u00a0antingen genom att givaren doppas in i mediet, som\u00a0d\u00e5 helt omsluter den temperaturk\u00e4nsliga delen, eller\u00a0genom att givaren l\u00e4gges an mot mediets yta. I b\u00e5da\u00a0fallen st\u00f6rs den befintliga v\u00e4rmestr\u00f6mningen eftersom\u00a0givaren transporterar v\u00e4rme fr\u00e5n mediet till\u00a0omgivningen.<br \/>\nSpeciellt vid m\u00e4tning av yttemperatur \u00e4r felet p.g.a.\u00a0v\u00e4rmeavledning framtr\u00e4dande. Ytans utstr\u00e5lning, och\u00a0d\u00e4rmed ocks\u00e5 temperaturprofilen, \u00e4ndras omkring\u00a0m\u00e4tst\u00e4llet. M\u00e4tnoggrannheten f\u00f6rb\u00e4ttras avsev\u00e4rt om\u00a0givaren har:<\/p>\n<p>liten massa och volym<br \/>\ngod v\u00e4rmekontakt<br \/>\nliten v\u00e4rmeledningsf\u00f6rm\u00e5ga till omgivningen<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8845&#8243; img_size=&#8221;large&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;matvardesomvandlare&#8221;]<br \/>\nM\u00e4tv\u00e4rdesomvandlare<br \/>\nM\u00e4tv\u00e4rdesomvandlare anv\u00e4nds f\u00f6r omvandling av en motst\u00e5ndsgivares resistansv\u00e4rde till en process-anpassad m\u00e4tsignal. F\u00f6r anslutning av givaren till omvandlaren till\u00e4mpas tre olika anslutningsmetoder: 2-, 3- och 4-ledaranslutning. I samtliga anslutnings\u00adformer s\u00e4nder omvandlaren en konstant str\u00f6m genom m\u00e4tmotst\u00e5ndet, som man sedan m\u00e4ter sp\u00e4nningsfallet \u00f6ver. Omvandlare tillverkas i 2- resp. 4-tr\u00e5dsutf\u00f6rande (ej att f\u00f6rv\u00e4xla med 2- resp. 4-ledaranslutning). I 4-tr\u00e5ds-utf\u00f6rande matas omvandlaren genom tv\u00e5 separata ledare (d\u00e4rav beteckningen separatmatad) skilda fr\u00e5n utg\u00e5ngens tv\u00e5 ledare.<br \/>\nI 2-tr\u00e5dsutf\u00f6rande matas omvandlaren via utg\u00e5ngens b\u00e5da ledare vilka d\u00e4rigenom uppfyller dubbla funktioner. D\u00e4rav f\u00f6ljer automatiskt att en 2-tr\u00e5dsomvandlares utsignal pga. egenf\u00f6rbrukningen ej kan g\u00e5 ned till 0, utan har ett l\u00e4gsta v\u00e4rde av 4 mA. Standardspannet (processnorm) blir d\u00e4rf\u00f6r 4-20 mA. Utsignalen fr\u00e5n en 4-tr\u00e5dsomvandlare kan d\u00e4remot f\u00e5s att anta godtyckliga processignalv\u00e4rden.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<br \/>\nIng\u00e5ng<br \/>\nM\u00e4tv\u00e4rdesomvandlare anv\u00e4nds f\u00f6r omvandling av en motst\u00e5ndsgivares resistansv\u00e4rde till en process-anpassad m\u00e4tsignal. F\u00f6r anslutning av givaren till omvandlaren till\u00e4mpas normalt tre olika anslutningsmetoder: 2-, 3- och 4-ledaranslutning. I samtliga anslutnings\u00adformer s\u00e4nder omvandlaren en konstant str\u00f6m genom m\u00e4tmotst\u00e5ndet, som man sedan m\u00e4ter sp\u00e4nningsfallet \u00f6ver. Det \u00e4r viktigt att m\u00e4tstr\u00f6mmen h\u00e5lls liten f\u00f6r att minimera egenuppv\u00e4rmningen. En bra omvandlare avger en m\u00e4tstr\u00f6m som ligger under 1 mA.<br \/>\n[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<br \/>\nUtg\u00e5ng<br \/>\nOmvandlare tillverkas i 2- resp. 4-tr\u00e5dsutf\u00f6rande (ej att f\u00f6rv\u00e4xla med 2- resp. 4-ledaranslutning). I 4-tr\u00e5ds-utf\u00f6rande matas omvandlaren genom tv\u00e5 separata ledare (d\u00e4rav beteckningen separatmatad) skilda fr\u00e5n utg\u00e5ngens tv\u00e5 ledare.<br \/>\nI 2-tr\u00e5dsutf\u00f6rande matas omvandlaren via utg\u00e5ngens b\u00e5da ledare vilka d\u00e4rigenom uppfyller dubbla funktioner. D\u00e4rav f\u00f6ljer automatiskt att en 2-tr\u00e5dsomvandlares utsignal pga. egenf\u00f6rbrukningen ej kan g\u00e5 ned till 0, utan har ett l\u00e4gsta v\u00e4rde av 4 mA. Standardspannet (processnorm) blir d\u00e4rf\u00f6r 4-20 mA. Utsignalen fr\u00e5n en 4-tr\u00e5dsomvandlare kan d\u00e4remot f\u00e5s att anta godtyckliga processignalv\u00e4rden som 0 &#8211; 20 mA, 4 \u2013 20 mA, 0-5 V eller 1 &#8211; 5 V.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221; el_id=&#8221;givarbrott&#8221;]<br \/>\nGivarbrott<br \/>\nDe stora p\u00e5frestningarna temperaturgivare uts\u00e4tts f\u00f6r kan medf\u00f6ra risk f\u00f6r elektriskt avbrott inuti givaren.\u00a0Avbrottet kan drabba tilledningarna eller ocks\u00e5 kan\u00a0m\u00e4tmotst\u00e5ndet skadas. Samtliga dessa fel g\u00e5r under\u00a0namnet givarbrott. Den vanligaste orsaken till givarbrott\u00a0\u00e4r vibrationer i eller omkring den kritiska\u00a0frekvensen. En modern omvandlare ger signal vid\u00a0givarbrott. Detta sker genom att utsignalen g\u00e5r till ett\u00a0f\u00f6rbest\u00e4mt v\u00e4rde, vanligast strax ovanf\u00f6r 20 mA.<br \/>\nKonsekvent givarbrottskydd inneb\u00e4r att omvandlaren signalerar, dvs utsignalen g\u00e5r till ett f\u00f6rutbest\u00e4mt v\u00e4rde, oavsett i vilken ledare avbrottet har \u00e4gt rum (viktigt att veta vid 3- eller 4-ledaranslutning). Hos INORs programmerbara omvandlare best\u00e4mmer anv\u00e4ndaren sj\u00e4lv utsignalens v\u00e4rde vid givarbrott.<br \/>\nOBS! N\u00e4r givarens isolationsmotst\u00e5nd sjunker under en viss niv\u00e5 kan det intr\u00e4ffa att omvandlaren uppfattar det l\u00e5ga isolationsmotst\u00e5ndet som ett m\u00e4tv\u00e4rde i st\u00e4llet f\u00f6r det motst\u00e5nd som m\u00e4tmotst\u00e5ndet intar. P\u00e5f\u00f6ljden blir att omvandlaren luras att tro att m\u00e4tkedjan \u00e4r intakt \u00e4ven sedan ett givarbrott \u00e4gt rum. De flesta INOR-omvandlare har en funktion, SmartSense, som kontinuerligt \u00f6vervakar temperaturgivarens isolationsresistans och ger signal n\u00e4r denna \u00e4r f\u00f6r l\u00e5g.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_single_image image=&#8221;8966&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;linjarisering&#8221;]<br \/>\nLinj\u00e4risering<br \/>\nMed temperaturlinj\u00e4risering menas att en omvandlare alltid l\u00e4mnar samma f\u00f6r\u00e4ndring av utsignalen f\u00f6r en viss f\u00f6r\u00e4ndring av in-temperaturen oberoende av var inom m\u00e4tspannet denna f\u00f6r\u00e4ndring sker. F\u00f6rh\u00e5llandet temperatur\/utsignal blir d\u00e4rf\u00f6r en r\u00e4t linje. F\u00f6r motst\u00e5ndslinj\u00e4ra omvandlare \u00e4r d\u00e4remot \u00f6verf\u00f6ringen olinj\u00e4r ur temperatur-h\u00e4nseende som medf\u00f6r olika stora f\u00f6r\u00e4ndringar av utsignalen inom m\u00e4tspannets olika delar. Hos digitala omvandlare kan man l\u00e4tt st\u00e4lla om mellan motst\u00e5nds- och temperaturlinj\u00e4ritet.[\/vc_column_text][vc_single_image image=&#8221;8866&#8243; img_size=&#8221;large&#8221; add_caption=&#8221;yes&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text el_id=&#8221;ledaranslutning&#8221;]<br \/>\n2-ledaranslutning<br \/>\nI en 2-ledaranslutning ligger motst\u00e5ndet fr\u00e5n anslutningsledningarna i serie med m\u00e4tmotst\u00e5ndet. F\u00f6r\u00e4ndringar i tilledningarnas motst\u00e5nd kommer d\u00e4rf\u00f6r att direkt p\u00e5verka m\u00e4tresultatet. P.g.a. de up\u00adpenbara nackdelarna anv\u00e4nds denna form s\u00e4llan och b\u00f6r anv\u00e4ndas med f\u00f6rsiktighet.<br \/>\nM\u00e4tfel p.g.a. ledningarnas motst\u00e5nd \u00e4r i regel cirka 2,6 \u00b0C per ohm f\u00f6r en Pt100-givare och 10 g\u00e5nger mindre f\u00f6r Pt1000. Om ledningsmotst\u00e5ndet \u00e4r k\u00e4nt, kan signalomvandlaren justeras manuellt f\u00f6r att kompens\u00adera ledningsmotst\u00e5ndet. Eftersom detta \u00e4r en fast jus\u00adtering, kommer f\u00f6r\u00e4ndringar i ledningsmotst\u00e5ndet p\u00e5 grund av temperaturvariationer inte att kompenseras.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8947&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;]<br \/>\n3-ledaranslutning<br \/>\nDetta \u00e4r den vanligast f\u00f6rekommande formen f\u00f6r anslutning. 3-ledaranslutning f\u00f6ruts\u00e4tter att resistansen i de tre ledarna \u00e4r lika. Normalt elimin\u00aderar den i stort sett inverkan av f\u00f6r\u00e4ndringar i tilledningarna s\u00e5 l\u00e4nge dessa f\u00f6r\u00e4ndringar \u00e4r lika i de tre ledarna (hos INORs IPAQ-signalomvandlare \u00e4r inverkan helt eliminerad). F\u00f6r omvandlare inbyggda i givarens anslutningshuvud \u00e4r 3-ledaranslutning den mest anv\u00e4nda metoden.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8948&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\n4-ledaranslutning<br \/>\n4-ledaranslutning anv\u00e4nds vid noggranna m\u00e4tningar. M\u00e4tstr\u00f6mmen leds genom tv\u00e5 ledningar och sp\u00e4nningsfallet m\u00e4ts \u00f6ver de tv\u00e5 \u00e5terst\u00e5ende. H\u00e4rigenom elimineras alla motst\u00e5ndsf\u00f6r\u00e4ndringar i tilledningarna, \u00e4ven n\u00e4r dessa skiljer sig fr\u00e5n varandra. De flesta moderna signalomvandlare st\u00f6djer denna rekommenderade anslutning.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8949&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<br \/>\nTillbaka till Temperaturskolan<br \/>\n[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":8677,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-temp.php","meta":{"footnotes":""},"class_list":["post-5539","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100 - INOR<\/title>\n<meta name=\"description\" content=\"F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100 - INOR\" \/>\n<meta property=\"og:description\" content=\"F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/\" \/>\n<meta property=\"og:site_name\" content=\"INOR\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-09T12:29:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/\",\"url\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/\",\"name\":\"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100 - INOR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/omvandlare-ingang-300x65.jpg\",\"datePublished\":\"2018-07-03T11:38:53+00:00\",\"dateModified\":\"2025-06-09T12:29:35+00:00\",\"description\":\"F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/#primaryimage\",\"url\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/omvandlare-ingang-300x65.jpg\",\"contentUrl\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/omvandlare-ingang-300x65.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/pt100-matosakerhet-och-matavvikelser\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Start\",\"item\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Temperaturskolan\",\"item\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#website\",\"url\":\"https:\\\/\\\/inor-gmbh.de\\\/\",\"name\":\"INOR\",\"description\":\"Specialists in industrial temperature measurement\",\"publisher\":{\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/inor-gmbh.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#organization\",\"name\":\"INOR Transmitter GmbH\",\"url\":\"https:\\\/\\\/inor-gmbh.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/inor.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/inor-logo-sm.png\",\"contentUrl\":\"https:\\\/\\\/inor.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/inor-logo-sm.png\",\"width\":103,\"height\":25,\"caption\":\"INOR Transmitter GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100 - INOR","description":"F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"sv_SE","og_type":"article","og_title":"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100 - INOR","og_description":"F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen.","og_url":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/","og_site_name":"INOR","article_modified_time":"2025-06-09T12:29:35+00:00","og_image":[{"url":"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg","type":"","width":"","height":""}],"twitter_misc":{"Ber\u00e4knad l\u00e4stid":"9 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/","url":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/","name":"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100 - INOR","isPartOf":{"@id":"https:\/\/inor-gmbh.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/#primaryimage"},"image":{"@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/#primaryimage"},"thumbnailUrl":"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg","datePublished":"2018-07-03T11:38:53+00:00","dateModified":"2025-06-09T12:29:35+00:00","description":"F\u00f6r att minimera m\u00e4tfelen, som ofr\u00e5nkomligt uppst\u00e5r\u00a0vid varje temperaturm\u00e4tning, \u00e4r det viktigt att k\u00e4nna till\u00a0de faktorer som p\u00e5verkar m\u00e4tningen.","breadcrumb":{"@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/#primaryimage","url":"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg","contentUrl":"https:\/\/inor.stagingidentitet.se\/wp-content\/uploads\/2018\/06\/omvandlare-ingang-300x65.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/pt100-matosakerhet-och-matavvikelser\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Start","item":"https:\/\/inor.stagingidentitet.se\/"},{"@type":"ListItem","position":2,"name":"Temperaturskolan","item":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/"},{"@type":"ListItem","position":3,"name":"M\u00e4tos\u00e4kerhet och m\u00e4tavvikelser f\u00f6r Pt100"}]},{"@type":"WebSite","@id":"https:\/\/inor-gmbh.de\/#website","url":"https:\/\/inor-gmbh.de\/","name":"INOR","description":"Specialists in industrial temperature measurement","publisher":{"@id":"https:\/\/inor-gmbh.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/inor-gmbh.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/inor-gmbh.de\/#organization","name":"INOR Transmitter GmbH","url":"https:\/\/inor-gmbh.de\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/inor-gmbh.de\/#\/schema\/logo\/image\/","url":"https:\/\/inor.com\/wp-content\/uploads\/2015\/09\/inor-logo-sm.png","contentUrl":"https:\/\/inor.com\/wp-content\/uploads\/2015\/09\/inor-logo-sm.png","width":103,"height":25,"caption":"INOR Transmitter GmbH"},"image":{"@id":"https:\/\/inor-gmbh.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/5539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5539"}],"version-history":[{"count":2,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/5539\/revisions"}],"predecessor-version":[{"id":38421,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/5539\/revisions\/38421"}],"up":[{"embeddable":true,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/8677"}],"wp:attachment":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}