{"id":20219,"date":"2022-05-10T12:37:46","date_gmt":"2022-05-10T12:37:46","guid":{"rendered":"https:\/\/www.krohne-inor.se\/?page_id=20219"},"modified":"2025-06-09T12:30:32","modified_gmt":"2025-06-09T12:30:32","slug":"vad-ar-hart","status":"publish","type":"page","link":"https:\/\/inor.stagingidentitet.se\/?page_id=20219","title":{"rendered":"Vad \u00e4r HART?"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h1>Vad \u00e4r HART?<\/h1>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<strong>HART Communication Protocol<\/strong>\u00a0(<em>Highway Addressable Remote Transducer<\/em>) \u00e4r ett analogt och digitalt kommunikationsprotokoll utformat f\u00f6r industriella automatiska processm\u00e4tningar. Den st\u00f6rsta f\u00f6rdelen \u00e4r att HART-protokollet kan kommunicera via \u00e4ldre 4-20 mA analoga instrumenteringsslingor och dela det befintliga ledarpar som anv\u00e4nds av v\u00e4rdsystemen.<\/p>\n<p>Protokollet utvecklades av Rosemount Inc. och byggde p\u00e5 den tidiga kommunikationsstandarden<br \/>\nBell 202 i mitten av 1980-talet som ett eget digitalt kommunikationsprotokoll f\u00f6r deras smarta f\u00e4ltinstrument. Det utvecklades snart till HART och 1986 blev det ett \u00f6ppet protokoll. Sedan dess har protokollets m\u00f6jligheter f\u00f6rb\u00e4ttrats genom successiva revideringar av specifikationen. HART-kommunikationsprotokollet \u00e4r en \u00f6ppen standard som \u00e4gs av medlemsf\u00f6retag i FieldComm Group, varav de flesta har HART-produkter p\u00e5 marknaden.<\/p>\n<p>&nbsp;<\/p>\n<p>F\u00f6rdelar med HART-protokollet<\/p>\n<ul>\n<li>Ett av de mest popul\u00e4ra industriprotokollen i dag, p\u00e5 grund av den enorma basen av installerade 4-20 mA-system i hela v\u00e4rlden.<\/li>\n<li>HART-protokollet har varit ett bra \u00f6verg\u00e5ngsprotokoll f\u00f6r anv\u00e4ndare som ville anv\u00e4nda de gamla 4-20 mA-signalerna, men som ville implementera ett &#8221;smart&#8221; protokoll.<\/li>\n<li>Produkter som anv\u00e4nder HART-protokollet f\u00f6r att tillhandah\u00e5lla b\u00e5de analoga 4-20 mA- och digitala signaler ger en flexibilitet som inte \u00e4r tillg\u00e4nglig med n\u00e5gon annan kommunikationsteknik.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>Hart-signalen, l\u00e4gen och meddelandestruktur<\/h2>\n<p>Den ursprungliga och fortfarande mest anv\u00e4nda versionen \u00e4r frequency shift keyed (&#8221;FSK&#8221;\u2026som har en hastighet p\u00e5 1200 bps) . Det speciella med denna \u00e4r att den anv\u00e4nder en l\u00e5gmodulation som \u00f6verlagras p\u00e5 den standardiserade 4-20 mA str\u00f6mkrets som har anv\u00e4nts i stor utstr\u00e4ckning f\u00f6r s\u00e5dana m\u00e4tningar.<\/p>\n<p>Eftersom HART-signalen \u00e4r liten och best\u00e5r av sinusv\u00e5gor \u00e4r dess medelv\u00e4rde noll och p\u00e5verkar inte n\u00e4mnv\u00e4rt noggrannheten hos den analoga str\u00f6msignalen, som d\u00e4rf\u00f6r fortfarande kan anv\u00e4ndas. Detta ger kompatibilitet med befintliga system, samtidigt som det m\u00f6jligg\u00f6r samtidig digital kommunikation f\u00f6r konfiguration av anordningen, statuskontroll, diagnostik och s\u00e5 vidare.<\/p>\n<p>Senare specifikationer omfattar ett alternativ med h\u00f6gre hastighet p\u00e5 9600 bps, och HART rev. 7 omfattar WirelessHART\u2122, som erbjuder h\u00f6ghastighetsfunktioner f\u00f6r radion\u00e4tverk med kort r\u00e4ckvidd som anv\u00e4nder ISM-bandet 2,4 GHz.[\/vc_column_text][vc_single_image image=&#8221;20220&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 1. Signal f\u00f6r FSK HART[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_single_image image=&#8221;20291&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 2. Struktur f\u00f6r FSK HART-meddelanden[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>Olika anv\u00e4ndningsm\u00f6jligheter<\/h2>\n<ul>\n<li>Master-Slave<\/li>\n<li>Punkt-till-punkt<\/li>\n<li>Multidrop<\/li>\n<li>Burst<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_column_text]<strong>Master-Slave<\/strong><\/p>\n<p>HART \u00e4r ett master-slave-kommunikationsprotokoll, vilket inneb\u00e4r att under normal drift initieras varje slavkommunikation (f\u00e4ltenhet) av en masterkommunikationsenhet. Tv\u00e5 masters kan anslutas till varje HART-slinga. Den prim\u00e4ra masterenheten \u00e4r i allm\u00e4nhet ett \u201ddistributed control system (DCS)\u201d, en \u201dprogrammable logic controller (PLC)\u201d eller en persondator (PC). Den sekund\u00e4ra masterenheten kan vara en handh\u00e5llen terminal eller en annan dator. Slavenheterna omfattar s\u00e4ndare, st\u00e4lldon och styrenheter som svarar p\u00e5 kommandon fr\u00e5n den prim\u00e4ra eller sekund\u00e4ra masterenheten. En minsta slingimpedans p\u00e5 230 \u03a9 kr\u00e4vs f\u00f6r kommunikation.[\/vc_column_text][vc_column_text]<strong>Punkt-till-punkt<\/strong><\/p>\n<p>I punkt-till-punkt anv\u00e4nds den traditionella 4-20 mA-signalen f\u00f6r att kommunicera en processvariabel, medan ytterligare processvariabler, konfigurationsparametrar och andra enhetsdata \u00f6verf\u00f6rs digitalt med hj\u00e4lp av HART-protokollet. Den analoga 4-20 mA-signalen p\u00e5verkas inte av HART-signalen och kan anv\u00e4ndas f\u00f6r styrning p\u00e5 normalt s\u00e4tt. Den digitala HART-kommunikationssignalen ger tillg\u00e5ng till sekund\u00e4ra variabler och annan data som kan anv\u00e4ndas f\u00f6r drift, drifts\u00e4ttning, underh\u00e5ll och diagnostik. Tryck kan till exempel skickas som 4-20 mA, vilket representerar ett tryckintervall, och temperatur kan skickas digitalt \u00f6ver samma ledningar. I punkt-till-punkt-l\u00e4ge kan den digitala delen av HART-protokollet ses som ett slags digitalt gr\u00e4nssnitt f\u00f6r en str\u00f6mslinga.[\/vc_column_text][vc_single_image image=&#8221;20230&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 3. Punkt-till-punkt[\/vc_column_text][vc_empty_space][vc_column_text]<strong>Multidrop<\/strong><\/p>\n<p>F\u00f6r multidrop kr\u00e4vs endast ett par kablar och, i f\u00f6rekommande fall, s\u00e4kerhetsbarri\u00e4rer och en extra str\u00f6mf\u00f6rs\u00f6rjning f\u00f6r upp till 15 f\u00e4ltenheter. Alla processv\u00e4rden \u00f6verf\u00f6rs digitalt. I multidrop \u00e4r alla f\u00e4ltenheters avropsadresser &gt; 0, och str\u00f6mmen genom varje enhet \u00e4r fixerad till ett minimiv\u00e4rde (typiskt 4 mA).<\/p>\n<p>Anv\u00e4nd multidrop-anslutning f\u00f6r \u00f6vervakningskontrollinstallationer som ligger l\u00e5ngt ifr\u00e5n varandra, t.ex. r\u00f6rledningar, \u00f6verf\u00f6ringsstationer och tankparker.[\/vc_column_text][vc_single_image image=&#8221;20255&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 4. Multidrop[\/vc_column_text][vc_empty_space][vc_column_text]<strong>Burst<\/strong><\/p>\n<p>Vissa HART-enheter st\u00f6der det valfria Burst-kommunikationsl\u00e4get. Burst m\u00f6jligg\u00f6r snabbare kommunikation (3-4 datauppdateringar per sekund). I Burst instruerar mastern slaven att kontinuerligt s\u00e4nda ett standard HART-svarmeddelande (t.ex. v\u00e4rdet p\u00e5 processvariabeln). Mastern tar emot meddelandet med den h\u00f6gre hastigheten tills den instruerar slaven att sluta med Burst.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h2>Vad \u00e4r en HART-revision?<\/h2>\n<p>En HART-revision definierar en standardupps\u00e4ttning av funktioner och funktionalitet f\u00f6r HART-protokollet. Revision 5 utvecklades f\u00f6r att f\u00f6rb\u00e4ttra konfigurationen och underh\u00e5llet av analoga enheter. Den utvecklades av Emerson och \u00f6ppnades f\u00f6r industrin f\u00f6r processautomatisering i slutet av 1980-talet s\u00e5 att anv\u00e4ndarna kunde best\u00e4lla instrument och system fr\u00e5n olika tillverkare och s\u00e4kerst\u00e4lla driftskompatibilitet.<\/p>\n<p>Revidering 6 lade till funktioner f\u00f6r att f\u00f6rb\u00e4ttra den digitala systemintegrationen av tr\u00e5dbundna HART-enheter. Den sl\u00e4pptes 2001, men mycket f\u00e5 tillverkare har utvecklat produkter baserade p\u00e5 denna revidering.<\/p>\n<p>Revidering 7 lade till funktioner f\u00f6r att optimera tr\u00e5dl\u00f6s kommunikation. Den ger ocks\u00e5 en enda standard f\u00f6r tr\u00e5dbunden och tr\u00e5dl\u00f6s HART-kommunikation. Standarden sl\u00e4pptes 2007. WirelessHART-enheter har funnits tillg\u00e4ngliga sedan 2008, medan produkter f\u00f6r tr\u00e5dbunden HART-revision 7 blev tillg\u00e4ngliga f\u00f6r n\u00e5gra \u00e5r sedan.[\/vc_column_text][vc_column_text]<\/p>\n<h2>Key HART Features<\/h2>\n<table style=\"width: 100%; height: 752px;\">\n<tbody>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\"><strong>Revision<\/strong><\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><strong>5<\/strong><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><strong>6<\/strong><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\"><strong>7<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 39px; width: 62.6538%;\">Analog Loop Check<\/td>\n<td style=\"height: 39px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 39px; width: 62.6538%;\">Tag (8 character)<\/td>\n<td style=\"height: 39px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 39px; width: 62.6538%;\">Device Calibration<\/td>\n<td style=\"height: 39px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 39px; width: 62.6538%;\">Device Configuration<\/td>\n<td style=\"height: 39px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 39px; width: 62.6538%;\">Broadcast Messaging (Burst)<\/td>\n<td style=\"height: 39px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 39px; width: 62.6538%;\">Multi-Variable Communication (4)<\/td>\n<td style=\"height: 39px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"height: 40px; width: 62.6538%;\">Primary Variable with status<\/td>\n<td style=\"height: 40px; width: 8.75513%; text-align: center;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 40px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 40px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Device ststus<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 63px;\">\n<td style=\"height: 10px; width: 62.6538%;\">Long Tag (32 character)<\/td>\n<td style=\"height: 10px; width: 8.75513%; text-align: center;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 10px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 10px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Locate Device<\/td>\n<td style=\"width: 8.75513%; height: 39px; text-align: center;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Digital Loop Check<\/td>\n<td style=\"width: 8.75513%; height: 39px; text-align: center;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">HART Software Lock<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Multi-Variable Satuses<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\">X<\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Wireless<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Expanded Manufacture ID<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Enhanced Multi-Variable Communication (8)<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Time Stamp<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Trends<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"width: 62.6538%; height: 39px;\">Synchronized Sampling<\/td>\n<td style=\"width: 8.75513%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54992%; text-align: center; height: 39px;\"><\/td>\n<td style=\"width: 8.54995%; text-align: center; height: 39px;\">X<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<strong>Device Description (DD):<\/strong><\/p>\n<p>En DD f\u00f6r en HART-f\u00e4ltenhet motsvarar ungef\u00e4r ett elektroniskt datablad. DDs eliminerar behovet f\u00f6r v\u00e4rdleverant\u00f6rer att utveckla och st\u00f6dja anpassade gr\u00e4nssnitt och drivrutiner. En DD ger en bild av alla parametrar och funktioner f\u00f6r en enhet p\u00e5 ett standardiserat spr\u00e5k.<\/p>\n<p>Field devices l\u00e4mnas in till FCG f\u00f6r kvalitetskontroll och registrering. Det g\u00f6r \u00e4ven DD-filer. De l\u00e4mnas in till FieldComm Group f\u00f6r registrering i DD-biblioteket. Kvalitetskontroller utf\u00f6rs p\u00e5 varje DD som l\u00e4mnas in f\u00f6r att s\u00e4kerst\u00e4lla att specifikationerna f\u00f6ljs, f\u00f6r att kontrollera att det inte finns n\u00e5gra konflikter med DD som redan \u00e4r registrerade och f\u00f6r att verifiera att de fungerar med standard HART-v\u00e4rdar.[\/vc_column_text][vc_column_text]<strong>Device Type Manager (DTM)<\/strong><\/p>\n<p>En Device Type Manager (DTM) \u00e4r en del av FDT-standarden som \u00e4r en programvarukomponent f\u00f6r en enhet som inneh\u00e5ller enhetsspecifika data, funktioner och logikelement. DTM:er kan str\u00e4cka sig fr\u00e5n ett enkelt grafiskt anv\u00e4ndargr\u00e4nssnitt f\u00f6r att st\u00e4lla in enhetsparametrar till en mycket sofistikerad till\u00e4mpning som t.ex. kan utf\u00f6ra komplexa ber\u00e4kningar f\u00f6r diagnostik och underh\u00e5ll eller implementera godtyckligt komplexa aff\u00e4rslogiker f\u00f6r kalibrering av enheter. DTM inneh\u00e5ller ocks\u00e5 FDT-kompatibla gr\u00e4nssnitt f\u00f6r att m\u00f6jligg\u00f6ra kommunikation med det anslutna systemet eller verktyget.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>INORs produkter med HART<\/h2>\n<p><a href=\"https:\/\/inor.stagingidentitet.se\/produkt\/ipaq-c520\/\">IPAQ C520<\/a>, <a href=\"https:\/\/inor.stagingidentitet.se\/produkt\/ipaq-r520\/\">IPAQ R520<\/a>, <a href=\"https:\/\/inor.stagingidentitet.se\/produkt\/ipaq-c530\/\">IPAQ C530<\/a>\u00a0och <a href=\"https:\/\/inor.stagingidentitet.se\/produkt\/ipaq-r530\/\">IPAQ R530<\/a> \u00e4r utrustade med HART. IPAQ C\/R520 \u00e4r HART revision 6 och IPAQ C\/R530 \u00e4r HART revison 7. Till respektive produkt finns certifikat och DD\/DTM filer att ladda ner.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;5313&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 520[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;12335&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 530[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<br \/>\nVad \u00e4r HART?<br \/>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]HART Communication Protocol\u00a0(Highway Addressable Remote Transducer) \u00e4r ett analogt och digitalt kommunikationsprotokoll utformat f\u00f6r industriella automatiska processm\u00e4tningar. Den st\u00f6rsta f\u00f6rdelen \u00e4r att HART-protokollet kan kommunicera via \u00e4ldre 4-20 mA analoga instrumenteringsslingor och dela det befintliga ledarpar som anv\u00e4nds av v\u00e4rdsystemen.<br \/>\nProtokollet utvecklades av Rosemount Inc. och byggde p\u00e5 den tidiga kommunikationsstandarden<br \/>\nBell 202 i mitten av 1980-talet som ett eget digitalt kommunikationsprotokoll f\u00f6r deras smarta f\u00e4ltinstrument. Det utvecklades snart till HART och 1986 blev det ett \u00f6ppet protokoll. Sedan dess har protokollets m\u00f6jligheter f\u00f6rb\u00e4ttrats genom successiva revideringar av specifikationen. HART-kommunikationsprotokollet \u00e4r en \u00f6ppen standard som \u00e4gs av medlemsf\u00f6retag i FieldComm Group, varav de flesta har HART-produkter p\u00e5 marknaden.<br \/>\n&nbsp;<br \/>\nF\u00f6rdelar med HART-protokollet<\/p>\n<p>Ett av de mest popul\u00e4ra industriprotokollen i dag, p\u00e5 grund av den enorma basen av installerade 4-20 mA-system i hela v\u00e4rlden.<br \/>\nHART-protokollet har varit ett bra \u00f6verg\u00e5ngsprotokoll f\u00f6r anv\u00e4ndare som ville anv\u00e4nda de gamla 4-20 mA-signalerna, men som ville implementera ett &#8221;smart&#8221; protokoll.<br \/>\nProdukter som anv\u00e4nder HART-protokollet f\u00f6r att tillhandah\u00e5lla b\u00e5de analoga 4-20 mA- och digitala signaler ger en flexibilitet som inte \u00e4r tillg\u00e4nglig med n\u00e5gon annan kommunikationsteknik.<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\nHart-signalen, l\u00e4gen och meddelandestruktur<br \/>\nDen ursprungliga och fortfarande mest anv\u00e4nda versionen \u00e4r frequency shift keyed (&#8221;FSK&#8221;\u2026som har en hastighet p\u00e5 1200 bps) . Det speciella med denna \u00e4r att den anv\u00e4nder en l\u00e5gmodulation som \u00f6verlagras p\u00e5 den standardiserade 4-20 mA str\u00f6mkrets som har anv\u00e4nts i stor utstr\u00e4ckning f\u00f6r s\u00e5dana m\u00e4tningar.<br \/>\nEftersom HART-signalen \u00e4r liten och best\u00e5r av sinusv\u00e5gor \u00e4r dess medelv\u00e4rde noll och p\u00e5verkar inte n\u00e4mnv\u00e4rt noggrannheten hos den analoga str\u00f6msignalen, som d\u00e4rf\u00f6r fortfarande kan anv\u00e4ndas. Detta ger kompatibilitet med befintliga system, samtidigt som det m\u00f6jligg\u00f6r samtidig digital kommunikation f\u00f6r konfiguration av anordningen, statuskontroll, diagnostik och s\u00e5 vidare.<br \/>\nSenare specifikationer omfattar ett alternativ med h\u00f6gre hastighet p\u00e5 9600 bps, och HART rev. 7 omfattar WirelessHART\u2122, som erbjuder h\u00f6ghastighetsfunktioner f\u00f6r radion\u00e4tverk med kort r\u00e4ckvidd som anv\u00e4nder ISM-bandet 2,4 GHz.[\/vc_column_text][vc_single_image image=&#8221;20220&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 1. Signal f\u00f6r FSK HART[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_single_image image=&#8221;20291&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 2. Struktur f\u00f6r FSK HART-meddelanden[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\nOlika anv\u00e4ndningsm\u00f6jligheter<\/p>\n<p>Master-Slave<br \/>\nPunkt-till-punkt<br \/>\nMultidrop<br \/>\nBurst<\/p>\n<p>[\/vc_column_text][vc_column_text]Master-Slave<br \/>\nHART \u00e4r ett master-slave-kommunikationsprotokoll, vilket inneb\u00e4r att under normal drift initieras varje slavkommunikation (f\u00e4ltenhet) av en masterkommunikationsenhet. Tv\u00e5 masters kan anslutas till varje HART-slinga. Den prim\u00e4ra masterenheten \u00e4r i allm\u00e4nhet ett \u201ddistributed control system (DCS)\u201d, en \u201dprogrammable logic controller (PLC)\u201d eller en persondator (PC). Den sekund\u00e4ra masterenheten kan vara en handh\u00e5llen terminal eller en annan dator. Slavenheterna omfattar s\u00e4ndare, st\u00e4lldon och styrenheter som svarar p\u00e5 kommandon fr\u00e5n den prim\u00e4ra eller sekund\u00e4ra masterenheten. En minsta slingimpedans p\u00e5 230 \u03a9 kr\u00e4vs f\u00f6r kommunikation.[\/vc_column_text][vc_column_text]Punkt-till-punkt<br \/>\nI punkt-till-punkt anv\u00e4nds den traditionella 4-20 mA-signalen f\u00f6r att kommunicera en processvariabel, medan ytterligare processvariabler, konfigurationsparametrar och andra enhetsdata \u00f6verf\u00f6rs digitalt med hj\u00e4lp av HART-protokollet. Den analoga 4-20 mA-signalen p\u00e5verkas inte av HART-signalen och kan anv\u00e4ndas f\u00f6r styrning p\u00e5 normalt s\u00e4tt. Den digitala HART-kommunikationssignalen ger tillg\u00e5ng till sekund\u00e4ra variabler och annan data som kan anv\u00e4ndas f\u00f6r drift, drifts\u00e4ttning, underh\u00e5ll och diagnostik. Tryck kan till exempel skickas som 4-20 mA, vilket representerar ett tryckintervall, och temperatur kan skickas digitalt \u00f6ver samma ledningar. I punkt-till-punkt-l\u00e4ge kan den digitala delen av HART-protokollet ses som ett slags digitalt gr\u00e4nssnitt f\u00f6r en str\u00f6mslinga.[\/vc_column_text][vc_single_image image=&#8221;20230&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 3. Punkt-till-punkt[\/vc_column_text][vc_empty_space][vc_column_text]Multidrop<br \/>\nF\u00f6r multidrop kr\u00e4vs endast ett par kablar och, i f\u00f6rekommande fall, s\u00e4kerhetsbarri\u00e4rer och en extra str\u00f6mf\u00f6rs\u00f6rjning f\u00f6r upp till 15 f\u00e4ltenheter. Alla processv\u00e4rden \u00f6verf\u00f6rs digitalt. I multidrop \u00e4r alla f\u00e4ltenheters avropsadresser &gt; 0, och str\u00f6mmen genom varje enhet \u00e4r fixerad till ett minimiv\u00e4rde (typiskt 4 mA).<br \/>\nAnv\u00e4nd multidrop-anslutning f\u00f6r \u00f6vervakningskontrollinstallationer som ligger l\u00e5ngt ifr\u00e5n varandra, t.ex. r\u00f6rledningar, \u00f6verf\u00f6ringsstationer och tankparker.[\/vc_column_text][vc_single_image image=&#8221;20255&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 4. Multidrop[\/vc_column_text][vc_empty_space][vc_column_text]Burst<br \/>\nVissa HART-enheter st\u00f6der det valfria Burst-kommunikationsl\u00e4get. Burst m\u00f6jligg\u00f6r snabbare kommunikation (3-4 datauppdateringar per sekund). I Burst instruerar mastern slaven att kontinuerligt s\u00e4nda ett standard HART-svarmeddelande (t.ex. v\u00e4rdet p\u00e5 processvariabeln). Mastern tar emot meddelandet med den h\u00f6gre hastigheten tills den instruerar slaven att sluta med Burst.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<br \/>\nVad \u00e4r en HART-revision?<br \/>\nEn HART-revision definierar en standardupps\u00e4ttning av funktioner och funktionalitet f\u00f6r HART-protokollet. Revision 5 utvecklades f\u00f6r att f\u00f6rb\u00e4ttra konfigurationen och underh\u00e5llet av analoga enheter. Den utvecklades av Emerson och \u00f6ppnades f\u00f6r industrin f\u00f6r processautomatisering i slutet av 1980-talet s\u00e5 att anv\u00e4ndarna kunde best\u00e4lla instrument och system fr\u00e5n olika tillverkare och s\u00e4kerst\u00e4lla driftskompatibilitet.<br \/>\nRevidering 6 lade till funktioner f\u00f6r att f\u00f6rb\u00e4ttra den digitala systemintegrationen av tr\u00e5dbundna HART-enheter. Den sl\u00e4pptes 2001, men mycket f\u00e5 tillverkare har utvecklat produkter baserade p\u00e5 denna revidering.<br \/>\nRevidering 7 lade till funktioner f\u00f6r att optimera tr\u00e5dl\u00f6s kommunikation. Den ger ocks\u00e5 en enda standard f\u00f6r tr\u00e5dbunden och tr\u00e5dl\u00f6s HART-kommunikation. Standarden sl\u00e4pptes 2007. WirelessHART-enheter har funnits tillg\u00e4ngliga sedan 2008, medan produkter f\u00f6r tr\u00e5dbunden HART-revision 7 blev tillg\u00e4ngliga f\u00f6r n\u00e5gra \u00e5r sedan.[\/vc_column_text][vc_column_text]<br \/>\nKey HART Features<\/p>\n<p>Revision<br \/>\n5<br \/>\n6<br \/>\n7<\/p>\n<p>Analog Loop Check<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Tag (8 character)<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Device Calibration<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Device Configuration<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Broadcast Messaging (Burst)<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Multi-Variable Communication (4)<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Primary Variable with status<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Device ststus<br \/>\nX<br \/>\nX<br \/>\nX<\/p>\n<p>Long Tag (32 character)<\/p>\n<p>X<br \/>\nX<\/p>\n<p>Locate Device<\/p>\n<p>X<br \/>\nX<\/p>\n<p>Digital Loop Check<\/p>\n<p>X<br \/>\nX<\/p>\n<p>HART Software Lock<\/p>\n<p>X<br \/>\nX<\/p>\n<p>Multi-Variable Satuses<\/p>\n<p>X<br \/>\nX<\/p>\n<p>Wireless<\/p>\n<p>X<\/p>\n<p>Expanded Manufacture ID<\/p>\n<p>X<\/p>\n<p>Enhanced Multi-Variable Communication (8)<\/p>\n<p>X<\/p>\n<p>Time Stamp<\/p>\n<p>X<\/p>\n<p>Trends<\/p>\n<p>X<\/p>\n<p>Synchronized Sampling<\/p>\n<p>X<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]Device Description (DD):<br \/>\nEn DD f\u00f6r en HART-f\u00e4ltenhet motsvarar ungef\u00e4r ett elektroniskt datablad. DDs eliminerar behovet f\u00f6r v\u00e4rdleverant\u00f6rer att utveckla och st\u00f6dja anpassade gr\u00e4nssnitt och drivrutiner. En DD ger en bild av alla parametrar och funktioner f\u00f6r en enhet p\u00e5 ett standardiserat spr\u00e5k.<br \/>\nField devices l\u00e4mnas in till FCG f\u00f6r kvalitetskontroll och registrering. Det g\u00f6r \u00e4ven DD-filer. De l\u00e4mnas in till FieldComm Group f\u00f6r registrering i DD-biblioteket. Kvalitetskontroller utf\u00f6rs p\u00e5 varje DD som l\u00e4mnas in f\u00f6r att s\u00e4kerst\u00e4lla att specifikationerna f\u00f6ljs, f\u00f6r att kontrollera att det inte finns n\u00e5gra konflikter med DD som redan \u00e4r registrerade och f\u00f6r att verifiera att de fungerar med standard HART-v\u00e4rdar.[\/vc_column_text][vc_column_text]Device Type Manager (DTM)<br \/>\nEn Device Type Manager (DTM) \u00e4r en del av FDT-standarden som \u00e4r en programvarukomponent f\u00f6r en enhet som inneh\u00e5ller enhetsspecifika data, funktioner och logikelement. DTM:er kan str\u00e4cka sig fr\u00e5n ett enkelt grafiskt anv\u00e4ndargr\u00e4nssnitt f\u00f6r att st\u00e4lla in enhetsparametrar till en mycket sofistikerad till\u00e4mpning som t.ex. kan utf\u00f6ra komplexa ber\u00e4kningar f\u00f6r diagnostik och underh\u00e5ll eller implementera godtyckligt komplexa aff\u00e4rslogiker f\u00f6r kalibrering av enheter. DTM inneh\u00e5ller ocks\u00e5 FDT-kompatibla gr\u00e4nssnitt f\u00f6r att m\u00f6jligg\u00f6ra kommunikation med det anslutna systemet eller verktyget.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;]<br \/>\nINORs produkter med HART<br \/>\nIPAQ C520, IPAQ R520, IPAQ C530\u00a0och IPAQ R530 \u00e4r utrustade med HART. IPAQ C\/R520 \u00e4r HART revision 6 och IPAQ C\/R530 \u00e4r HART revison 7. Till respektive produkt finns certifikat och DD\/DTM filer att ladda ner.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;5313&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 520[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;12335&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 530[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row]<\/p>\n","protected":false},"author":12,"featured_media":0,"parent":8677,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-temp.php","meta":{"footnotes":""},"class_list":["post-20219","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Vad \u00e4r HART? - INOR<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Vad \u00e4r HART? - INOR\" \/>\n<meta property=\"og:description\" content=\"[vc_row][vc_column][vc_column_text] Vad \u00e4r HART? [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]HART Communication Protocol\u00a0(Highway Addressable Remote Transducer) \u00e4r ett analogt och digitalt kommunikationsprotokoll utformat f\u00f6r industriella automatiska processm\u00e4tningar. Den st\u00f6rsta f\u00f6rdelen \u00e4r att HART-protokollet kan kommunicera via \u00e4ldre 4-20 mA analoga instrumenteringsslingor och dela det befintliga ledarpar som anv\u00e4nds av v\u00e4rdsystemen. Protokollet utvecklades av Rosemount Inc. och byggde p\u00e5 den tidiga kommunikationsstandarden Bell 202 i mitten av 1980-talet som ett eget digitalt kommunikationsprotokoll f\u00f6r deras smarta f\u00e4ltinstrument. Det utvecklades snart till HART och 1986 blev det ett \u00f6ppet protokoll. Sedan dess har protokollets m\u00f6jligheter f\u00f6rb\u00e4ttrats genom successiva revideringar av specifikationen. HART-kommunikationsprotokollet \u00e4r en \u00f6ppen standard som \u00e4gs av medlemsf\u00f6retag i FieldComm Group, varav de flesta har HART-produkter p\u00e5 marknaden. &nbsp; F\u00f6rdelar med HART-protokollet Ett av de mest popul\u00e4ra industriprotokollen i dag, p\u00e5 grund av den enorma basen av installerade 4-20 mA-system i hela v\u00e4rlden. HART-protokollet har varit ett bra \u00f6verg\u00e5ngsprotokoll f\u00f6r anv\u00e4ndare som ville anv\u00e4nda de gamla 4-20 mA-signalerna, men som ville implementera ett &#8221;smart&#8221; protokoll. Produkter som anv\u00e4nder HART-protokollet f\u00f6r att tillhandah\u00e5lla b\u00e5de analoga 4-20 mA- och digitala signaler ger en flexibilitet som inte \u00e4r tillg\u00e4nglig med n\u00e5gon annan kommunikationsteknik. [\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Hart-signalen, l\u00e4gen och meddelandestruktur Den ursprungliga och fortfarande mest anv\u00e4nda versionen \u00e4r frequency shift keyed (&#8221;FSK&#8221;\u2026som har en hastighet p\u00e5 1200 bps) . Det speciella med denna \u00e4r att den anv\u00e4nder en l\u00e5gmodulation som \u00f6verlagras p\u00e5 den standardiserade 4-20 mA str\u00f6mkrets som har anv\u00e4nts i stor utstr\u00e4ckning f\u00f6r s\u00e5dana m\u00e4tningar. Eftersom HART-signalen \u00e4r liten och best\u00e5r av sinusv\u00e5gor \u00e4r dess medelv\u00e4rde noll och p\u00e5verkar inte n\u00e4mnv\u00e4rt noggrannheten hos den analoga str\u00f6msignalen, som d\u00e4rf\u00f6r fortfarande kan anv\u00e4ndas. Detta ger kompatibilitet med befintliga system, samtidigt som det m\u00f6jligg\u00f6r samtidig digital kommunikation f\u00f6r konfiguration av anordningen, statuskontroll, diagnostik och s\u00e5 vidare. Senare specifikationer omfattar ett alternativ med h\u00f6gre hastighet p\u00e5 9600 bps, och HART rev. 7 omfattar WirelessHART\u2122, som erbjuder h\u00f6ghastighetsfunktioner f\u00f6r radion\u00e4tverk med kort r\u00e4ckvidd som anv\u00e4nder ISM-bandet 2,4 GHz.[\/vc_column_text][vc_single_image image=&#8221;20220&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 1. Signal f\u00f6r FSK HART[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_single_image image=&#8221;20291&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 2. Struktur f\u00f6r FSK HART-meddelanden[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Olika anv\u00e4ndningsm\u00f6jligheter Master-Slave Punkt-till-punkt Multidrop Burst [\/vc_column_text][vc_column_text]Master-Slave HART \u00e4r ett master-slave-kommunikationsprotokoll, vilket inneb\u00e4r att under normal drift initieras varje slavkommunikation (f\u00e4ltenhet) av en masterkommunikationsenhet. Tv\u00e5 masters kan anslutas till varje HART-slinga. Den prim\u00e4ra masterenheten \u00e4r i allm\u00e4nhet ett \u201ddistributed control system (DCS)\u201d, en \u201dprogrammable logic controller (PLC)\u201d eller en persondator (PC). Den sekund\u00e4ra masterenheten kan vara en handh\u00e5llen terminal eller en annan dator. Slavenheterna omfattar s\u00e4ndare, st\u00e4lldon och styrenheter som svarar p\u00e5 kommandon fr\u00e5n den prim\u00e4ra eller sekund\u00e4ra masterenheten. En minsta slingimpedans p\u00e5 230 \u03a9 kr\u00e4vs f\u00f6r kommunikation.[\/vc_column_text][vc_column_text]Punkt-till-punkt I punkt-till-punkt anv\u00e4nds den traditionella 4-20 mA-signalen f\u00f6r att kommunicera en processvariabel, medan ytterligare processvariabler, konfigurationsparametrar och andra enhetsdata \u00f6verf\u00f6rs digitalt med hj\u00e4lp av HART-protokollet. Den analoga 4-20 mA-signalen p\u00e5verkas inte av HART-signalen och kan anv\u00e4ndas f\u00f6r styrning p\u00e5 normalt s\u00e4tt. Den digitala HART-kommunikationssignalen ger tillg\u00e5ng till sekund\u00e4ra variabler och annan data som kan anv\u00e4ndas f\u00f6r drift, drifts\u00e4ttning, underh\u00e5ll och diagnostik. Tryck kan till exempel skickas som 4-20 mA, vilket representerar ett tryckintervall, och temperatur kan skickas digitalt \u00f6ver samma ledningar. I punkt-till-punkt-l\u00e4ge kan den digitala delen av HART-protokollet ses som ett slags digitalt gr\u00e4nssnitt f\u00f6r en str\u00f6mslinga.[\/vc_column_text][vc_single_image image=&#8221;20230&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 3. Punkt-till-punkt[\/vc_column_text][vc_empty_space][vc_column_text]Multidrop F\u00f6r multidrop kr\u00e4vs endast ett par kablar och, i f\u00f6rekommande fall, s\u00e4kerhetsbarri\u00e4rer och en extra str\u00f6mf\u00f6rs\u00f6rjning f\u00f6r upp till 15 f\u00e4ltenheter. Alla processv\u00e4rden \u00f6verf\u00f6rs digitalt. I multidrop \u00e4r alla f\u00e4ltenheters avropsadresser &gt; 0, och str\u00f6mmen genom varje enhet \u00e4r fixerad till ett minimiv\u00e4rde (typiskt 4 mA). Anv\u00e4nd multidrop-anslutning f\u00f6r \u00f6vervakningskontrollinstallationer som ligger l\u00e5ngt ifr\u00e5n varandra, t.ex. r\u00f6rledningar, \u00f6verf\u00f6ringsstationer och tankparker.[\/vc_column_text][vc_single_image image=&#8221;20255&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 4. Multidrop[\/vc_column_text][vc_empty_space][vc_column_text]Burst Vissa HART-enheter st\u00f6der det valfria Burst-kommunikationsl\u00e4get. Burst m\u00f6jligg\u00f6r snabbare kommunikation (3-4 datauppdateringar per sekund). I Burst instruerar mastern slaven att kontinuerligt s\u00e4nda ett standard HART-svarmeddelande (t.ex. v\u00e4rdet p\u00e5 processvariabeln). Mastern tar emot meddelandet med den h\u00f6gre hastigheten tills den instruerar slaven att sluta med Burst.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Vad \u00e4r en HART-revision? En HART-revision definierar en standardupps\u00e4ttning av funktioner och funktionalitet f\u00f6r HART-protokollet. Revision 5 utvecklades f\u00f6r att f\u00f6rb\u00e4ttra konfigurationen och underh\u00e5llet av analoga enheter. Den utvecklades av Emerson och \u00f6ppnades f\u00f6r industrin f\u00f6r processautomatisering i slutet av 1980-talet s\u00e5 att anv\u00e4ndarna kunde best\u00e4lla instrument och system fr\u00e5n olika tillverkare och s\u00e4kerst\u00e4lla driftskompatibilitet. Revidering 6 lade till funktioner f\u00f6r att f\u00f6rb\u00e4ttra den digitala systemintegrationen av tr\u00e5dbundna HART-enheter. Den sl\u00e4pptes 2001, men mycket f\u00e5 tillverkare har utvecklat produkter baserade p\u00e5 denna revidering. Revidering 7 lade till funktioner f\u00f6r att optimera tr\u00e5dl\u00f6s kommunikation. Den ger ocks\u00e5 en enda standard f\u00f6r tr\u00e5dbunden och tr\u00e5dl\u00f6s HART-kommunikation. Standarden sl\u00e4pptes 2007. WirelessHART-enheter har funnits tillg\u00e4ngliga sedan 2008, medan produkter f\u00f6r tr\u00e5dbunden HART-revision 7 blev tillg\u00e4ngliga f\u00f6r n\u00e5gra \u00e5r sedan.[\/vc_column_text][vc_column_text] Key HART Features  Revision 5 6 7  Analog Loop Check X X X  Tag (8 character) X X X  Device Calibration X X X  Device Configuration X X X  Broadcast Messaging (Burst) X X X  Multi-Variable Communication (4) X X X  Primary Variable with status X X X  Device ststus X X X  Long Tag (32 character) X X  Locate Device X X  Digital Loop Check X X  HART Software Lock X X  Multi-Variable Satuses X X  Wireless  X  Expanded Manufacture ID  X  Enhanced Multi-Variable Communication (8)  X  Time Stamp  X  Trends  X  Synchronized Sampling  X  [\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]Device Description (DD): En DD f\u00f6r en HART-f\u00e4ltenhet motsvarar ungef\u00e4r ett elektroniskt datablad. DDs eliminerar behovet f\u00f6r v\u00e4rdleverant\u00f6rer att utveckla och st\u00f6dja anpassade gr\u00e4nssnitt och drivrutiner. En DD ger en bild av alla parametrar och funktioner f\u00f6r en enhet p\u00e5 ett standardiserat spr\u00e5k. Field devices l\u00e4mnas in till FCG f\u00f6r kvalitetskontroll och registrering. Det g\u00f6r \u00e4ven DD-filer. De l\u00e4mnas in till FieldComm Group f\u00f6r registrering i DD-biblioteket. Kvalitetskontroller utf\u00f6rs p\u00e5 varje DD som l\u00e4mnas in f\u00f6r att s\u00e4kerst\u00e4lla att specifikationerna f\u00f6ljs, f\u00f6r att kontrollera att det inte finns n\u00e5gra konflikter med DD som redan \u00e4r registrerade och f\u00f6r att verifiera att de fungerar med standard HART-v\u00e4rdar.[\/vc_column_text][vc_column_text]Device Type Manager (DTM) En Device Type Manager (DTM) \u00e4r en del av FDT-standarden som \u00e4r en programvarukomponent f\u00f6r en enhet som inneh\u00e5ller enhetsspecifika data, funktioner och logikelement. DTM:er kan str\u00e4cka sig fr\u00e5n ett enkelt grafiskt anv\u00e4ndargr\u00e4nssnitt f\u00f6r att st\u00e4lla in enhetsparametrar till en mycket sofistikerad till\u00e4mpning som t.ex. kan utf\u00f6ra komplexa ber\u00e4kningar f\u00f6r diagnostik och underh\u00e5ll eller implementera godtyckligt komplexa aff\u00e4rslogiker f\u00f6r kalibrering av enheter. DTM inneh\u00e5ller ocks\u00e5 FDT-kompatibla gr\u00e4nssnitt f\u00f6r att m\u00f6jligg\u00f6ra kommunikation med det anslutna systemet eller verktyget.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;] INORs produkter med HART IPAQ C520, IPAQ R520, IPAQ C530\u00a0och IPAQ R530 \u00e4r utrustade med HART. IPAQ C\/R520 \u00e4r HART revision 6 och IPAQ C\/R530 \u00e4r HART revison 7. Till respektive produkt finns certifikat och DD\/DTM filer att ladda ner.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;5313&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 520[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;12335&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 530[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/\" \/>\n<meta property=\"og:site_name\" content=\"INOR\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-09T12:30:32+00:00\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/vad-ar-hart\\\/\",\"url\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/vad-ar-hart\\\/\",\"name\":\"Vad \u00e4r HART? - INOR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#website\"},\"datePublished\":\"2022-05-10T12:37:46+00:00\",\"dateModified\":\"2025-06-09T12:30:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/vad-ar-hart\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/vad-ar-hart\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/vad-ar-hart\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Start\",\"item\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Temperaturskolan\",\"item\":\"https:\\\/\\\/inor.stagingidentitet.se\\\/temperaturskolan\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Vad \u00e4r HART?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#website\",\"url\":\"https:\\\/\\\/inor-gmbh.de\\\/\",\"name\":\"INOR\",\"description\":\"Specialists in industrial temperature measurement\",\"publisher\":{\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/inor-gmbh.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#organization\",\"name\":\"INOR Transmitter GmbH\",\"url\":\"https:\\\/\\\/inor-gmbh.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/inor.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/inor-logo-sm.png\",\"contentUrl\":\"https:\\\/\\\/inor.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/inor-logo-sm.png\",\"width\":103,\"height\":25,\"caption\":\"INOR Transmitter GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/inor-gmbh.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Vad \u00e4r HART? - INOR","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"sv_SE","og_type":"article","og_title":"Vad \u00e4r HART? - INOR","og_description":"[vc_row][vc_column][vc_column_text] Vad \u00e4r HART? [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]HART Communication Protocol\u00a0(Highway Addressable Remote Transducer) \u00e4r ett analogt och digitalt kommunikationsprotokoll utformat f\u00f6r industriella automatiska processm\u00e4tningar. Den st\u00f6rsta f\u00f6rdelen \u00e4r att HART-protokollet kan kommunicera via \u00e4ldre 4-20 mA analoga instrumenteringsslingor och dela det befintliga ledarpar som anv\u00e4nds av v\u00e4rdsystemen. Protokollet utvecklades av Rosemount Inc. och byggde p\u00e5 den tidiga kommunikationsstandarden Bell 202 i mitten av 1980-talet som ett eget digitalt kommunikationsprotokoll f\u00f6r deras smarta f\u00e4ltinstrument. Det utvecklades snart till HART och 1986 blev det ett \u00f6ppet protokoll. Sedan dess har protokollets m\u00f6jligheter f\u00f6rb\u00e4ttrats genom successiva revideringar av specifikationen. HART-kommunikationsprotokollet \u00e4r en \u00f6ppen standard som \u00e4gs av medlemsf\u00f6retag i FieldComm Group, varav de flesta har HART-produkter p\u00e5 marknaden. &nbsp; F\u00f6rdelar med HART-protokollet Ett av de mest popul\u00e4ra industriprotokollen i dag, p\u00e5 grund av den enorma basen av installerade 4-20 mA-system i hela v\u00e4rlden. HART-protokollet har varit ett bra \u00f6verg\u00e5ngsprotokoll f\u00f6r anv\u00e4ndare som ville anv\u00e4nda de gamla 4-20 mA-signalerna, men som ville implementera ett &#8221;smart&#8221; protokoll. Produkter som anv\u00e4nder HART-protokollet f\u00f6r att tillhandah\u00e5lla b\u00e5de analoga 4-20 mA- och digitala signaler ger en flexibilitet som inte \u00e4r tillg\u00e4nglig med n\u00e5gon annan kommunikationsteknik. [\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Hart-signalen, l\u00e4gen och meddelandestruktur Den ursprungliga och fortfarande mest anv\u00e4nda versionen \u00e4r frequency shift keyed (&#8221;FSK&#8221;\u2026som har en hastighet p\u00e5 1200 bps) . Det speciella med denna \u00e4r att den anv\u00e4nder en l\u00e5gmodulation som \u00f6verlagras p\u00e5 den standardiserade 4-20 mA str\u00f6mkrets som har anv\u00e4nts i stor utstr\u00e4ckning f\u00f6r s\u00e5dana m\u00e4tningar. Eftersom HART-signalen \u00e4r liten och best\u00e5r av sinusv\u00e5gor \u00e4r dess medelv\u00e4rde noll och p\u00e5verkar inte n\u00e4mnv\u00e4rt noggrannheten hos den analoga str\u00f6msignalen, som d\u00e4rf\u00f6r fortfarande kan anv\u00e4ndas. Detta ger kompatibilitet med befintliga system, samtidigt som det m\u00f6jligg\u00f6r samtidig digital kommunikation f\u00f6r konfiguration av anordningen, statuskontroll, diagnostik och s\u00e5 vidare. Senare specifikationer omfattar ett alternativ med h\u00f6gre hastighet p\u00e5 9600 bps, och HART rev. 7 omfattar WirelessHART\u2122, som erbjuder h\u00f6ghastighetsfunktioner f\u00f6r radion\u00e4tverk med kort r\u00e4ckvidd som anv\u00e4nder ISM-bandet 2,4 GHz.[\/vc_column_text][vc_single_image image=&#8221;20220&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 1. Signal f\u00f6r FSK HART[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_single_image image=&#8221;20291&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 2. Struktur f\u00f6r FSK HART-meddelanden[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Olika anv\u00e4ndningsm\u00f6jligheter Master-Slave Punkt-till-punkt Multidrop Burst [\/vc_column_text][vc_column_text]Master-Slave HART \u00e4r ett master-slave-kommunikationsprotokoll, vilket inneb\u00e4r att under normal drift initieras varje slavkommunikation (f\u00e4ltenhet) av en masterkommunikationsenhet. Tv\u00e5 masters kan anslutas till varje HART-slinga. Den prim\u00e4ra masterenheten \u00e4r i allm\u00e4nhet ett \u201ddistributed control system (DCS)\u201d, en \u201dprogrammable logic controller (PLC)\u201d eller en persondator (PC). Den sekund\u00e4ra masterenheten kan vara en handh\u00e5llen terminal eller en annan dator. Slavenheterna omfattar s\u00e4ndare, st\u00e4lldon och styrenheter som svarar p\u00e5 kommandon fr\u00e5n den prim\u00e4ra eller sekund\u00e4ra masterenheten. En minsta slingimpedans p\u00e5 230 \u03a9 kr\u00e4vs f\u00f6r kommunikation.[\/vc_column_text][vc_column_text]Punkt-till-punkt I punkt-till-punkt anv\u00e4nds den traditionella 4-20 mA-signalen f\u00f6r att kommunicera en processvariabel, medan ytterligare processvariabler, konfigurationsparametrar och andra enhetsdata \u00f6verf\u00f6rs digitalt med hj\u00e4lp av HART-protokollet. Den analoga 4-20 mA-signalen p\u00e5verkas inte av HART-signalen och kan anv\u00e4ndas f\u00f6r styrning p\u00e5 normalt s\u00e4tt. Den digitala HART-kommunikationssignalen ger tillg\u00e5ng till sekund\u00e4ra variabler och annan data som kan anv\u00e4ndas f\u00f6r drift, drifts\u00e4ttning, underh\u00e5ll och diagnostik. Tryck kan till exempel skickas som 4-20 mA, vilket representerar ett tryckintervall, och temperatur kan skickas digitalt \u00f6ver samma ledningar. I punkt-till-punkt-l\u00e4ge kan den digitala delen av HART-protokollet ses som ett slags digitalt gr\u00e4nssnitt f\u00f6r en str\u00f6mslinga.[\/vc_column_text][vc_single_image image=&#8221;20230&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 3. Punkt-till-punkt[\/vc_column_text][vc_empty_space][vc_column_text]Multidrop F\u00f6r multidrop kr\u00e4vs endast ett par kablar och, i f\u00f6rekommande fall, s\u00e4kerhetsbarri\u00e4rer och en extra str\u00f6mf\u00f6rs\u00f6rjning f\u00f6r upp till 15 f\u00e4ltenheter. Alla processv\u00e4rden \u00f6verf\u00f6rs digitalt. I multidrop \u00e4r alla f\u00e4ltenheters avropsadresser &gt; 0, och str\u00f6mmen genom varje enhet \u00e4r fixerad till ett minimiv\u00e4rde (typiskt 4 mA). Anv\u00e4nd multidrop-anslutning f\u00f6r \u00f6vervakningskontrollinstallationer som ligger l\u00e5ngt ifr\u00e5n varandra, t.ex. r\u00f6rledningar, \u00f6verf\u00f6ringsstationer och tankparker.[\/vc_column_text][vc_single_image image=&#8221;20255&#8243; img_size=&#8221;full&#8221;][vc_column_text]Bild 4. Multidrop[\/vc_column_text][vc_empty_space][vc_column_text]Burst Vissa HART-enheter st\u00f6der det valfria Burst-kommunikationsl\u00e4get. Burst m\u00f6jligg\u00f6r snabbare kommunikation (3-4 datauppdateringar per sekund). I Burst instruerar mastern slaven att kontinuerligt s\u00e4nda ett standard HART-svarmeddelande (t.ex. v\u00e4rdet p\u00e5 processvariabeln). Mastern tar emot meddelandet med den h\u00f6gre hastigheten tills den instruerar slaven att sluta med Burst.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Vad \u00e4r en HART-revision? En HART-revision definierar en standardupps\u00e4ttning av funktioner och funktionalitet f\u00f6r HART-protokollet. Revision 5 utvecklades f\u00f6r att f\u00f6rb\u00e4ttra konfigurationen och underh\u00e5llet av analoga enheter. Den utvecklades av Emerson och \u00f6ppnades f\u00f6r industrin f\u00f6r processautomatisering i slutet av 1980-talet s\u00e5 att anv\u00e4ndarna kunde best\u00e4lla instrument och system fr\u00e5n olika tillverkare och s\u00e4kerst\u00e4lla driftskompatibilitet. Revidering 6 lade till funktioner f\u00f6r att f\u00f6rb\u00e4ttra den digitala systemintegrationen av tr\u00e5dbundna HART-enheter. Den sl\u00e4pptes 2001, men mycket f\u00e5 tillverkare har utvecklat produkter baserade p\u00e5 denna revidering. Revidering 7 lade till funktioner f\u00f6r att optimera tr\u00e5dl\u00f6s kommunikation. Den ger ocks\u00e5 en enda standard f\u00f6r tr\u00e5dbunden och tr\u00e5dl\u00f6s HART-kommunikation. Standarden sl\u00e4pptes 2007. WirelessHART-enheter har funnits tillg\u00e4ngliga sedan 2008, medan produkter f\u00f6r tr\u00e5dbunden HART-revision 7 blev tillg\u00e4ngliga f\u00f6r n\u00e5gra \u00e5r sedan.[\/vc_column_text][vc_column_text] Key HART Features  Revision 5 6 7  Analog Loop Check X X X  Tag (8 character) X X X  Device Calibration X X X  Device Configuration X X X  Broadcast Messaging (Burst) X X X  Multi-Variable Communication (4) X X X  Primary Variable with status X X X  Device ststus X X X  Long Tag (32 character) X X  Locate Device X X  Digital Loop Check X X  HART Software Lock X X  Multi-Variable Satuses X X  Wireless  X  Expanded Manufacture ID  X  Enhanced Multi-Variable Communication (8)  X  Time Stamp  X  Trends  X  Synchronized Sampling  X  [\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]Device Description (DD): En DD f\u00f6r en HART-f\u00e4ltenhet motsvarar ungef\u00e4r ett elektroniskt datablad. DDs eliminerar behovet f\u00f6r v\u00e4rdleverant\u00f6rer att utveckla och st\u00f6dja anpassade gr\u00e4nssnitt och drivrutiner. En DD ger en bild av alla parametrar och funktioner f\u00f6r en enhet p\u00e5 ett standardiserat spr\u00e5k. Field devices l\u00e4mnas in till FCG f\u00f6r kvalitetskontroll och registrering. Det g\u00f6r \u00e4ven DD-filer. De l\u00e4mnas in till FieldComm Group f\u00f6r registrering i DD-biblioteket. Kvalitetskontroller utf\u00f6rs p\u00e5 varje DD som l\u00e4mnas in f\u00f6r att s\u00e4kerst\u00e4lla att specifikationerna f\u00f6ljs, f\u00f6r att kontrollera att det inte finns n\u00e5gra konflikter med DD som redan \u00e4r registrerade och f\u00f6r att verifiera att de fungerar med standard HART-v\u00e4rdar.[\/vc_column_text][vc_column_text]Device Type Manager (DTM) En Device Type Manager (DTM) \u00e4r en del av FDT-standarden som \u00e4r en programvarukomponent f\u00f6r en enhet som inneh\u00e5ller enhetsspecifika data, funktioner och logikelement. DTM:er kan str\u00e4cka sig fr\u00e5n ett enkelt grafiskt anv\u00e4ndargr\u00e4nssnitt f\u00f6r att st\u00e4lla in enhetsparametrar till en mycket sofistikerad till\u00e4mpning som t.ex. kan utf\u00f6ra komplexa ber\u00e4kningar f\u00f6r diagnostik och underh\u00e5ll eller implementera godtyckligt komplexa aff\u00e4rslogiker f\u00f6r kalibrering av enheter. DTM inneh\u00e5ller ocks\u00e5 FDT-kompatibla gr\u00e4nssnitt f\u00f6r att m\u00f6jligg\u00f6ra kommunikation med det anslutna systemet eller verktyget.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;&#8221;] INORs produkter med HART IPAQ C520, IPAQ R520, IPAQ C530\u00a0och IPAQ R530 \u00e4r utrustade med HART. IPAQ C\/R520 \u00e4r HART revision 6 och IPAQ C\/R530 \u00e4r HART revison 7. Till respektive produkt finns certifikat och DD\/DTM filer att ladda ner.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;5313&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 520[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;12335&#8243; img_size=&#8221;medium&#8221;][vc_column_text]IPAQ 530[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row]","og_url":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/","og_site_name":"INOR","article_modified_time":"2025-06-09T12:30:32+00:00","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"7 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/","url":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/","name":"Vad \u00e4r HART? - INOR","isPartOf":{"@id":"https:\/\/inor-gmbh.de\/#website"},"datePublished":"2022-05-10T12:37:46+00:00","dateModified":"2025-06-09T12:30:32+00:00","breadcrumb":{"@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/vad-ar-hart\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Start","item":"https:\/\/inor.stagingidentitet.se\/"},{"@type":"ListItem","position":2,"name":"Temperaturskolan","item":"https:\/\/inor.stagingidentitet.se\/temperaturskolan\/"},{"@type":"ListItem","position":3,"name":"Vad \u00e4r HART?"}]},{"@type":"WebSite","@id":"https:\/\/inor-gmbh.de\/#website","url":"https:\/\/inor-gmbh.de\/","name":"INOR","description":"Specialists in industrial temperature measurement","publisher":{"@id":"https:\/\/inor-gmbh.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/inor-gmbh.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/inor-gmbh.de\/#organization","name":"INOR Transmitter GmbH","url":"https:\/\/inor-gmbh.de\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/inor-gmbh.de\/#\/schema\/logo\/image\/","url":"https:\/\/inor.com\/wp-content\/uploads\/2015\/09\/inor-logo-sm.png","contentUrl":"https:\/\/inor.com\/wp-content\/uploads\/2015\/09\/inor-logo-sm.png","width":103,"height":25,"caption":"INOR Transmitter GmbH"},"image":{"@id":"https:\/\/inor-gmbh.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/20219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20219"}],"version-history":[{"count":2,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/20219\/revisions"}],"predecessor-version":[{"id":38424,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/20219\/revisions\/38424"}],"up":[{"embeddable":true,"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=\/wp\/v2\/pages\/8677"}],"wp:attachment":[{"href":"https:\/\/inor.stagingidentitet.se\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}